3.2.10 Oscillator Control Register (OSCC)
Register Description: Oscillator Control Register
Register Name: OSCC
Register Address: Module 05h, Index 0Ch
Bits 15 to 12, 4, and 3: Reserved. Read returns 0, write ignored.
Bits 11 and 10: High-Frequency Crystal Output Capacitance Select 1 and 0 (HFOC1 and HFOC0). See
Section 5
for details on
these bits.
Bits 9 and 8: High-Frequency Crystal Input Capacitance Select 1 and 0 (HFIC1 and HFIC0). See
Section 5
for details on these bits.
Bits 7 to 5: ADC Clock Divider Bits 2 to 0 (ADCCD2 to ADCCD0). These bits determine the ADC clock frequency that is divided
down from the system clock. The MAXQ7665/MAXQ7666 ADC uses the divided-system clock to clock the multiplexer front-end selec-
tion, track and hold acquisition, and each step of the successive approximation conversion. Note that there is no ADC clock in stop
mode.
Bit 2: External High-Frequency Clock Enable (EXTHF). See
Section 5
for details on this bit.
Bit 1: Internal RC Oscillator Enable (RCE). See
Section 5
for details on this bit.
Bit 0: High-Frequency Crystal Oscillator Enable (HFE). See
Section 5
for details on this bit.
MAXQ7665/MAXQ7666 Users Guide
3-16
Bit #
15 14 13 12 11 10 9 8
Name — — — — HFOC1 HFOC0 HFIC1 HFIC0
Reset 0 0 0 0 0 0 0 0
Access r r r r rw rw rw rw
Bit #
76543210
Name ADCCD2 ADCCD1 ADCCD0 EXTHF RCE HFE
Reset 0 0 0 0 0 0 1 0
Access rw rw rw r r rw rw rw
r = read, w = write (Note that some clock control bits may have locking mechanisms for write.)
Note: This register is cleared to 0002h on power-on reset and is not affected by other forms of reset.
ADCCD2:ADCCD0 DIVIDE RATIO ADC CLOCK
000 1 (default) ADC Clock = System Clock
001 2 ADC Clock = System Clock/2
010 4 ADC Clock = System Clock/4
011 8 ADC Clock = System Clock/8
100 16 ADC Clock = System Clock/16
101–111
Reserved,
divide by 16 if set
ADC Clock = System Clock/16